Compact system capable of performing many new functions such as sensitivity (S/N 150: RMS) and ultra-high-speed (48,000 nm/min) at the highest level of its class. Having Fixed Bandwidth 10nm This product is designed for fulfill the basic needs of customer. This instrument easily meets the requirement in material research, drug analysis, biochemical and clinical testing, water quality control, food safety testing and other areas of qualitative and quantitative analysis
High quality Control and Quality assurance: High quality Xenon light source and Photo multiplier tube detectors and instruments to provide sufficient light intensity signal and the detection sensitivity
| Highlights |
|
|---|---|
| Wavelength | {"Range(Ex.&Em.)":"200nm - 900nm","Accuracy":"\u00b1 1nm","Repeatability":"\u00b1 0.5nm","Scan Speed":"Multi-Speed Level, Maximum at 48000 nm\/min","Slit(Ex. & Em.)":"10 nm"} |
| Light Source | 150W Xenon lamp (Hamamatsu) |
| Intensity Range | 0.00-10000 |
| Detection Limit | ≤ 1x10-10 g/ml (Quinine Sulphate Solution) |
| S/N Ratio | Raman peak of water: S/N≥150(10 nm slit) |
| Peak Intensity Reproducibility | ≤ 1.5% |
| Linear correlation coefficient | Slope≥ 0.995 |
| Stability(10min.) | Value Limit:±1.5% |
| Monochromator | C – T diffraction grating monochromator |
| Detector | PMT |
| Data Output | USB |
| Power | 200 W |
| Power Supply | AC220v± 22v, 50Hz±1Hz, |
| Dimensions | 380x445x310(mm) |
| Weight | 12kg |
Main Instrument – 1, Pro Sofware -1, Instrument Manual – 1, Fuse – 2No.Power cable -1, USB Cable – 1no., Quartz Fluorescence Sample cell 10mm – 1 pair
| # | Accessories | Functions |
|---|---|---|
| 1 | Single sample rack | Conventional Liquid Fluorescence Sample |
| 2 | Multi-Purpose Fluorescent Sample Rack Holder | Base holder |
| 3 | Octave Filter | Remove the interference of frequency doubling |
| 4 | 200 µl micro scale centrifuge tube rack | For centrifuge tube fluorescence measurement |
| 5 | Membrane sample rack | For membrane sample |
| 6 | Powder Sample rack | For powder samples |
| 7 | Auto Polarization Filter | Adjust the polarization light |
Analysis of Trace levels of
Biological Samples in Clinical Examination, Medicine and Bio-Chemistry
Constituents in Food
Components immeasurable by AAS in organic & Inorganic Chemistry
Analysis of Drugs, Quality Control of Pharmaceuticals & Study of metabolism of Medicines in Pharmacy & Pharmacology
Monitoring & Study of Air & Food pollutants, Environmental Sanitation etc., in pollution control
Assays requiring Fluorescent Analysis beyond Quantification – Polarization
For Anisotropy studies of molecular Dynamics
For complete photophysical model of the molecules (Absorbance, Fluorescence and Polarization Accessories together)
Analysis of Trace levels of
Biological Samples in Clinical Examination, Medicine and Bio-Chemistry
Constituents in Food
Components immeasurable by AAS in organic & Inorganic Chemistry
Analysis of Drugs, Quality Control of Pharmaceuticals & Study of metabolism of Medicines in Pharmacy & Pharmacology
Monitoring & Study of Air & Food pollutants, Environmental Sanitation etc., in pollution control
Assays requiring Fluorescent Analysis beyond Quantification – Polarization
For Anisotropy studies of molecular Dynamics
For complete photophysical model of the molecules (Absorbance, Fluorescence and Polarization Accessories together)
Main Instrument – 1, Pro Sofware -1, Instrument Manual – 1, Fuse – 2No.Power cable -1, USB Cable – 1no., Quartz Fluorescence Sample cell 10mm – 1 pair
| # | Accessories | Functions |
|---|---|---|
| 1 | Single sample rack | Conventional Liquid Fluorescence Sample |
| 2 | Multi-Purpose Fluorescent Sample Rack Holder | Base holder |
| 3 | Octave Filter | Remove the interference of frequency doubling |
| 4 | 200 µl micro scale centrifuge tube rack | For centrifuge tube fluorescence measurement |
| 5 | Membrane sample rack | For membrane sample |
| 6 | Powder Sample rack | For powder samples |
| 7 | Auto Polarization Filter | Adjust the polarization light |