Atomic Absorption Spectrophotometer AAS-7150
Atomic Absorption Spectrophotometer AAS-7150

Atomic Absorption Spectrophotometer AAS-7150

Atomic Absorption Spectrophotometer is fully PC controlled. It can be flexibly equipped with optional graphite furnace, auto sampler, and hydride generator. Unique optical mechanical design, safe and convenient flame system, optional background correction technologies, as well as convenient functions provided by the PC Software. This AAS is more accurate, reproducible and fulfill the requirement of all type of customer applications
This AAS is available in FIVE Configurations;
Flame Analysis only (Optional: 8 Lamp Turret)
Flame + Graphite Furnace
Flame + Graphite Furnace + Auto Sampler
Graphite Furnace only
Graphite Furnace + Auto Sampler

Request Quote Catalog
1 Review(s)

$4000.00

Highlights
  • Flame Analysis only (Optional: 8 Lamp Turret)
  • Flame + Graphite Furnace
  • Flame + Graphite Furnace + Auto Sampler
  • Graphite Furnace only
  • Graphite Furnace + Auto Sampler
Wavelength {"Range":"190 - 900nm","Accuracy":"\u00b1 0.2nm","Repeatability":"\u00b1 0.1nm","Scanning Speed":"","Setting":""}
Baseline Drift ≤0.0025ABS/30min (Cu)
Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 0.7nm, 1.0nm, 2.0nm
Resolution Spectral BW:0.2nm can separate Mn two lines (279.8nm, valley/peak energy ratio <20%
Optical System Czerny-Turner, integrated optical platform, fully closed optical system
Grating 1800 lines/ mm
Burner Head 100mm standard, Optional:50mm nitrous oxide Burner
Nebulizer High-Efficiency glass nebulizer
Baseline Drift (Flame)
Characteristic concentration Cu ≤ 0.025 µg/ml
Detection Limit
5 PPM Cu Abs. > 8ABS
Reproducibility ≤ 0.5%
Gas Flow Control Automatic
Ignition PC Control
Safety Precautions Automatically cut off gas in case of low pressure, Power Failure, Flame shut-off and Burner mismatched
Background Correction Technology D2 background correction
Dimensions 700mm*550mm*530mm
  • Main Features: Compact, delicate appearance and Easy to use
    Unique optical design
    Safe, reliable and convenient flame system
    Sensitive and Reliable
    Flexible Configuration
    Optional: 50 mm Burner, Hydride Generator, Graphite Furnace Compact and Easy to Use: Combined flame and graphite furnace makes the system compact. High-Performance of auto-sampler conventionally and reliably improves laboratory efficiency

  • Agricultural
    Geological
    Education and Research
    Institutes
    Food
    Petrochemical
    Environmental
    Mining
    Pharmaceuticals
    etc.

100mm burner+Capillary+1 lamp (Cu)+ Air Compressor + PC software

Main Features: Compact, delicate appearance and Easy to use
Unique optical design
Safe, reliable and convenient flame system
Sensitive and Reliable
Flexible Configuration
Optional: 50 mm Burner, Hydride Generator, Graphite Furnace Compact and Easy to Use: Combined flame and graphite furnace makes the system compact. High-Performance of auto-sampler conventionally and reliably improves laboratory efficiency

Agricultural
Geological
Education and Research
Institutes
Food
Petrochemical
Environmental
Mining
Pharmaceuticals
etc.

100mm burner+Capillary+1 lamp (Cu)+ Air Compressor + PC software

8 Lamp(Only Flame System),50mm burner, Hydride Generator, Graphite Furnace System, Auto Sampler

Related Products

Get Quote